Attention Makers

CATEGORY: EDUCATION

SKIN FILM BIOSENSOR

MAKERS: UTHAYAKUMAR

The human body signal biosensor will be very useful to detect any signal from the human body. The present invention will be used as biosensor to monitor the functions of organs such as heart, kidney, spinal cord, stomach and etc., Hence it will be one of the most useful invention in the medical health care industry. Point to point care of the human body signals at various stages of any patient is the current requirement in the health care field. The present invention consists of 22 electrodes(all the electrodes were coated with silver one side and other side was coated with gold and copper) embedded at various locations in the plant tissue film sheet and measured the voltages developed between each and every electrode. The size of the plant tissue film sheet was 11cm x 9cm and thickness of the sheet was 1mm. The present invention fabrication cost is very less and also easy produce with various requirements. The developed voltage between reference electrode( one side was gold coated and the backside was coated with silver (black probe) and Copper plate (one side was coated with copper and the other side was coated with silver (Red probe) was -19.5mVolts and the voltage developed between gold plate to the copper plate was 20.5 mVolts. The developed voltage between reference electrode(black probe) and Copper plate(red probe) was 12.8mVolts and -16.7 mVolts. The developed voltage between surface of the plant tissue film sheet (red probe) and Copper plate(black probe) was 62.2mVolts and 70.0 mVolts. The developed voltage between Copper plate(black probe) and sliver plate was 9.4mvolts whereas the voltage developed between copper plate and gold plate was 35.0 mVolts. The developed voltage between copper plate(black probe) and gold plate was 12.9 mVolts, the voltage created between copper plate and gold plate was 38.6 mVolts respectively. The developed voltage between copper plate(black probe) and silver plate was -3.3mVolts and the voltage created between copper plate and gold plate was 11.9 mVolts. The developed voltage between copper plate(black probe) and gold plate was 10. 3mVolts and the voltage developed between opposite directions of silver plate and gold plate was -9.4 mVolts respectively. The developed voltage between gold plate(black probe) and gold plate(red probe) 17.4mVolts and the voltage developed between opposite directions of silver plate and gold was -12.4 mVolts respectively. The developed voltage between gold plate(black probe) and silver plate -23.6mVolts and the voltage developed between opposite directions of two gold plates were 35.1 mVolts respectively. The developed voltage between gold plate(black probe) and silver plate 12.5mVolts and the voltage developed between copper plate and silver in the same direction at a distance of 23mm was 10.2 mVolts respectively. The voltage developed between copper plate and gold plate in the same direction at a distance of 7.5cm was -43.5 mVolts and the developed voltage between gold plate(red probe) and silver plate(surface) at a distance of 5cm was -78.1mVolts respectively.

Home Previous Next

Vote Share Comment